Serial NO :S00315061-EN
Date of Editing : 2020-05-26
Questions : RS-485 I/O status monitoring through 701Client Scada For Restroom Emergency Assist Alarm
Problem Solving :
We recommend to use RS-485 I/O module AR-403-IO-0404M-E or AR-403-IO-0404M for this application
AR-403-IO-0404M-E
AR-403-IO-0404M
※ Connect 485 Module to computer via USB converter AR-321-CM and use “Commview” to select working mode “Standard”
1. Select Node ID
2. Click "Read" to read parameter from module
3. Select "Standard" mode
4. Click "Write" to update parameter to module
Operation & Setting :
Number DI 0 ~ 511, Number 511 fixed for Fire input
Number DO 512~ 1023, DO0 corresponding Number 512, DO1 corresponding Number 513… and so on
Step1 :Create a new graphic picture
Draw a picture “Restroom Emergency Display.jpg” and save it into the path of C:\Program Files (x86)\701Client
Step2 Click Edit à Graphic contents and enters the setting menu
Click “Browser” to select the picture “Restroom Emergency Display.jpg” we will use
Step3 Follow the next steps to create each DI point for different site
For example , we use the first AR-403-IO-0404M (Node ID 001) connect 4 emergency buttons and the second AR-403-IO-0404M (Node ID 002) connect 4 emergency buttons
The first AR-403-IO-0404 as Controller 001, its DI0~3 use I/O number 0~3
The second AR-403-IO-0404 as Controller 002, its DI0~3 use I/O number 4~7
Before edit, we should create Bmp File under the path of C:\Program Files (x86)\701Client\PopGra
We create two Bmp file Emergency 0 and Emergency 1 as two status of DI
Step4 After done setting, click “Exit” to leave the menu, we will see 8 Emergency icon on the picture
We can drag each icon to the different location
Step5 “file” --> “Save as” to save the setting as one new picture with the name “Restroom Emergency Display” under the path of C:\Program Files (x86)\701Client
Press the iconto make the picture to run
Step6 When the emergency button is pressed, 701Client will receive the log and display the status on Scada.
Step7 Click “Edit” --> “Pop Up Parameters”
Step8 The Menu “POP IO table” will be displayed, click “Panel File” and replace from “default. pic” to “Restroom Emergency Display.pic”.
After finish, please make sure to save your setting .
Step9 When any DI status is changed, the picture of Restroom Emergency Display will pop-up to remind the manager .