►SOYAL - How to Order
content
(Tick to jump directly to the content)
1. Access Control Basic Terminology such as multi-door, single-door, all-in one control and separate control
1-1 Multi-Door Control Panel
1-2 All-in-one Controller (including RFID card reading, user data management and control functions)
1-3 Proximity Reader (Excluding user data management and control functions)
2. Choose suitable hardware and software according to application requirements: Various applications Introduction
2-1 Introduction of basic access control system structure and accessories
2-2 Single door / Dual door / Multi-door
2-3 Standalone Mode & Networking Mode
3. Selection according to hardware specification: controller function comparison table
4. Classification and Application of Electric Lock
1. Access Control Basic Terminology such as multi-door, single-door, all-in one control and separate control
The chapter will introduce the relationship of Multi-door control panel, All-in-one Controller and Proximity Reader in the access control architecture and provide customers with the most basic concept of SOYAL access control system structure
The hierarchical relationship in the access control structure is: Multi-door Control panel > All-in-one Controller > Proximity Reader
1-1 Multi-Door Control Panel
► More Detailed Introduction
1-2 All-in-one Controller (including RFID card reading, user data management and control functions)
SOYAL's all-in one controllers can be divided into Home version (H series) controller and Enterprise version (E series) controller according to their functions:
>Home version (H series) controller models list:
>Enterprise version (E series) controller models list:
► More Detailed Introduction
1-3 Proximity Reader (Excluding user data management and control functions)
>Proximity Reader Models List:
► More Detailed Introduction
2. Application Structure and Function Introduction
2-1 Introduction of basic access control system structure and accessories ► More Detailed Introdution
2-2 Single Door/Dual Door/Multi-Door
(1) Basic single door access control system (entry control, no exit control) ► More Detailed Introduction
(2) Basic single door access control system (both entry and exit are controlled) ► More Detailed Introduction
(3) Dual Door Access Control System ► More Detailed Introduction
(4) Networking Multi-Door Control System ► More Detailed Introduction
2-3 Standalone Mode & Networking Mode
(1) Standalone Access Control System Structure ► More Detailed Introduction
(2) Networking Access Control System Structure ► More Detailed Introduction
3. Selection according to hardware specification:controller function comparison table
3-1 User Capacity / Transaction Record / Access Indentification / Door Capacity
Partial Model No. Supported
All Model No. Supported
Parameter | Enterprise E Series Controller | Home H Series Controller | Reader (K/U Series) |
Contril Panel (AR-716-E16) | All-in-One Access Controller | Contril Panel (AR-716-E02) | All-in-One Access Controller |
User Capacity | User Capacity | 16,000 | 32,000 | 65,000 | 16,000 | 32,000 | 65,000 | 1,024 | 1,024 | 3,000 | — |
Floors Number | 64 | 32 | 16 | 64 | 32 | 16 | — | 16~32 | 16~32 | — |
Event Log | 32,000 | 32,000 | 1,100 | 1,100 | 1,500 | — |
Access Identification | Fingerprint | — | .png) | — | — | — |
Face Recognition | — | .png) | — | — | — |
QR Code | — | .png) | — | — | .png) |
Doors | 1.5 Doors | — | — | — | .png) | — |
2 Doors | — | .png) | .png) | — | — |
16 Doors | .png) | — | — | — | — |
3-2 Communication
All Model No. Supported
Optional by Order
Parameter | Enterprise E Series Controller | Home H Series Controller | Reader (K/U Series) |
Contril Panel (AR-716-E16) | All-in-One Access Controller | Contril Panel (AR-716-E02) | All-in-One Access Controller |
connect computer | RS485 | SSC | SSC | SSC | SSC | — |
TCP/IP | SSC | SSC | — | — | — |
Extension Serial Port | UART | — | .png) | — | — | — |
Wiegand | Input(24~64Bits) | Input(24~64Bits) | Input(24~64Bits) |
3-3 Frequency / UID Bits
Partial Model No. Supported
All Model No. Supported
3-4 DI/DO
Partial Model No. Supported
All Model No. Supported
Parameter | Enterprise E Series Controller | Home H Series Controller | Reader (K/U Series) |
Contril Panel (AR-716-E16) | All-in-One Access Controller | Contril Panel (AR-716-E02) | All-in-One Access Controller |
DI | Egress | .png) | .png) | — | .png) | — |
Door Status | .png) | .png) | — | .png) | — |
Door Bell | — | .png) | — | .png) | — |
Open Collect Output | Door Lock Output | .png) | .png) | — | .png) | — |
Alarm Output | .png) | .png) | — | .png) | — |
Door Bell Output | — | .png) | — | .png) | — |
Security Output | — | .png) | — | .png) | — |
Arming Output | — | .png) | — | .png) | — |
Duress Output | — | .png) | — | .png) | — |
Tamper Switch | — | .png) | — | .png) | — |
Wiegand Input | Red LED | .png) | — | — | — | .png) |
Green LED | .png) | — | — | — | .png) |
Buzzer | .png) | — | — | — | .png) |
Wiegand Output | Red LED | — | .png) | — | .png) | — |
Green LED | — | .png) | — | .png) | — |
Buzzer | — | .png) | — | .png) | — |
3-5 Hardware Specification
Partial Model No. Supported
All Model No. Supported
Parameter | Enterprise E Series Controller | Home H Series Controller | Reader (K/U Series) |
Contril Panel (AR-716-E16) | All-in-One Access Controller | Contril Panel (AR-716-E02) | All-in-One Access Controller |
Power Voltage | 9-24VDC | .png) | .png) | — | .png) | .png) |
Ingress Protection | IP54 | — | — | — | .png) | .png) |
IP55 | — | .png) | — | .png) | .png) |
IP56 | — | .png) | — | .png) | .png) |
IP65 | — | .png) | — | — | — |
IP66 | — | .png) | — | — | — |
Housing Material | Zinc Alloy | — | .png) | — | .png) | .png) |
PC | — | .png) | — | .png) | .png) |
3-6 Other
All Model No. Supported
4. Classification and Application of Electric Lock
SOYAL offers the following 4 types of electric locks, the electric door lock can be controlled to open or close by SOYAL controller
Electric Lock | Suitable Installation Site | Relay Time Setting |
.png) Electric Bolt Lock | • Two-ways glass door (It can be embedded installation and is not limited by the opening door direction) • Public Area (Fail-Safe) • Automatic Door (Electric Bolt Lock for Automatic Door) • In high security places, the fail-safe lock with European lock cylinder is recommended | General anode lock 15 seconds Anode lock with door open button connection Point 0.5sec |
.png) Electronic Magnetic Lock | Suitable for installing on wooden door, aluminum door; Waterproof magnetic lock is suitable for outdoor installation | 15 sec |
.png) Electric Strike | Suitable for wooden door, private space and high security area, After installation, the function of mechanical lock can be retained at the same time | 0.2 sec |
.png) Cabinet Lock | Locker and mailbox | 0.2 sec |
SOYAL Software , Product More Function Introduction
(Tick to jump directly to the content)
► 701 Software Related Function
► Access Related Function
► SOYAL Security Related Function